ZWD832 Dual-Channel RF Remote Decoder IC — 9 Modes, 30-Code Memory, SOP-8 Plug & Play

Pre-programmed dual-channel independent RF remote decoder IC with EV1527/PT2262 auto-detect, 9 output modes, 30-code EEPROM memory, 2.5–5.5 V supply and a complete reference circuit — no firmware development required.

Technical specifications

PackageSOP-8
Channels2 fully independent (OUT1 / OUT2)
ProtocolsEV1527 learning code / PT2262 fixed code, automatic recognition
Remote memory30 remotes (shared pool), EEPROM, power-off retention
Output modes9 per channel — momentary / toggle / interlock / EV1527 batch / 5 timers
Timer options10 s / 30 s / 60 s / 180 s / 600 s
Supply voltageDC 2.5–5.5 V (absolute max 2.0–5.5 V)
Output drive≤ 20 mA per channel; use a transistor/MOSFET for relays
RF frequencySet by external receiver module — 315 / 433.92 / 868 / 915 MHz
Operating temperature-40°C to +85°C

Protocols & interfaces

EV1527PT2262315 MHz / 433.92 MHz RF

ZWD832 dual-channel RF remote decoder IC, SOP-8 package

Product overview

ZWD832 is a ready-to-use dual-channel wireless remote decoder from Zowinda Technology Co., Ltd. Its firmware is pre-burned at the factory — simply power it up, learn a transmitter, and it works. No coding, no programming and no external MCU. Two fully independent decoder channels, automatic EV1527 / PT2262 recognition, nine selectable output modes and a 30-code memory are all packed into one SOP-8 package.

The two channels are genuinely independent: each learns its own remotes, selects its own output mode and never interferes with the other. Built-in EEPROM stores up to 30 remotes shared across both channels, and learned codes survive power loss permanently.

ZWD832 SOP-8 chip illustration

At a glance

SOP-829302.5–5.5 V
PackageIndependent channelsOutput modesRemote slotsWide supply

Key features

  • True dual-channel — two completely independent outputs. Each channel learns its own remotes and selects its own mode without interfering with the other.
  • Auto protocol detect — automatically recognizes EV1527 rolling code and PT2262 fixed code; no manual switching or jumper settings.
  • 30-code memory — built-in EEPROM stores up to 30 remotes shared across both channels; learned codes survive power loss permanently.
  • Nine output modes — momentary, toggle, interlock, EV1527 batch and five timer options from 10 s to 600 s, selectable by key presses.
  • Plug and play — factory-pre-programmed firmware initializes automatically at power-up; learn a remote with a button, no software development.
  • Wide voltage range — operates from 2.5 V to 5.5 V DC, compatible with lithium batteries, dry cells and regulated 5 V supplies.

Pin configuration

A compact 8-pin SOP package. Pin 7 (RF) accepts the data output of any superheterodyne or super-regenerative receiver module.

ZWD832 pinout diagram, SOP-8 top view

PinNameTypeFunction
1VCCPowerPositive supply, 2.5–5.5 V DC; place a 100 nF bypass capacitor nearby
2OUT2OutputChannel 2 control output, active high; ≤ 20 mA drive, use a transistor/MOSFET for a relay
3LEDOutputShared status LED output, active high; indicates learn, success and clear states
4SET2InputChannel 2 learn / setting key, active low (press to GND)
5SET1InputChannel 1 learn / setting key, active low; same behavior as SET2
6OUT1OutputChannel 1 control output, active high; same as OUT2
7RFInputRF data input (shared), connect to the DO pin of a receiver module; internal pull-up
8GNDGroundSupply ground and common signal reference

Electrical characteristics

Absolute maximum ratings (Ta = 25°C)

ParameterSymbolValueUnit
Supply voltageVCC2.0 ~ 5.5V
Operating temperatureTopr−40 ~ +85°C
Storage temperatureTstg−65 ~ +150°C
I/O pin currentIIO±25mA

Recommended operating conditions

ParameterSymbolValueUnit
Supply voltageVCC2.5 / 5.0 / 5.5 (min / typ / max)V
RF frequencyfRF315 / 433.92 (set by receiver module)MHz
Output high voltageVOHVCC × 0.8V
Output low voltageVOL≤ 0.6V

Nine selectable operating modes

To choose a mode: hold the SET key about 4 seconds to enter learn mode (LED blinks 3 times), then short-press SET the number of times shown below. After about 2 seconds the LED stays on to confirm.

PressesModeDescription
1MomentaryOutput closes while the remote button is held, releases on release — like a doorbell
2Toggle (self-lock)Each press flips the output ON ↔ OFF and holds the state; most widely used
3InterlockLearn an ON key and an OFF key; mutually exclusive, ideal for motor forward/reverse
4EV1527 batchOne press learns all four buttons: 1st → 30 s, 2nd → 60 s, 3rd → 180 s, 4th → 600 s (EV1527 only)
5Timer 10 sTrigger closes the output, then automatically opens after 10 seconds
6Timer 30 sTrigger closes the output, then automatically opens after 30 seconds
7Timer 60 sTrigger closes the output, then automatically opens after 60 seconds
8Timer 180 sTrigger closes the output, then automatically opens after 180 seconds
9Timer 600 sTrigger closes the output, then automatically opens after 600 seconds (10 minutes)

Choosing a mode: the number of short presses on SET equals the mode number (1 momentary / 2 toggle / 3 interlock / 4 batch / 5–9 timer). If unsure, choose mode 2 (toggle) — it behaves just like a normal light switch.

How to learn a remote

All operations are performed on the SET key of the corresponding channel (SET1 for CH1, SET2 for CH2). The two channels never affect each other.

  1. Hold SET ≈ 4 s — enter learn mode for that channel. LED: solid on → blinks 3×.
  2. Short-press to select — each press adds 1 to the mode number. LED: 1 blink per press.
  3. Press remote key — within the 20 s window, press any remote button. LED: blinks 3× = learned.
  4. Auto exit — the chip returns to standby. Hold SET 4 s again to add another remote (max 30). Timeout: 20 s → 4 blinks.

LED status quick reference

LED behaviorMeaning
Solid while holding SETLong-press threshold reached (≈ 4 s learn / ≈ 10 s clear)
3 blinks after ≈ 4 s holdEntered learn mode for that channel
1 blink per short pressMode number increased by one
Solid after mode selectedMode confirmed, waiting for RF signal (20 s)
3 blinks on RF signalLearn successful — remote saved
3 blinks then stays on (interlock)Step 1 done — now press the OFF key
4 blinks after 20 s idleLearn timed out — nothing saved
4 blinks after ≈ 10 s holdClear successful — all remotes erased (both channels)

Manual toggle without a remote: in normal (non-learn) state, a short press of a SET key flips that channel's output directly — useful when the remote is lost, out of battery, or during installation. Keep the press shorter than 4 seconds to avoid entering learn mode.

Clear all remotes: hold either SET key about 10 seconds until the LED blinks 4 times and goes out. This erases all learned remotes from both channels — use with care. The 30 memory slots are shared, not 15 per channel.

Key timing reference: short press (< 4 s) = manual toggle · hold ≈ 4 s = enter learn · hold ≈ 10 s = clear all. The three thresholds are clearly separated to prevent accidental triggering.

What each mode actually does

① Momentary — hold to act, release to reset. A "press to connect, release to disconnect" switch: hold the remote button and the output closes; let go and it opens instantly. Like a doorbell button. Best for doorbells, sirens, jog relays, electric actuators and pumps that should run only while held.

② Toggle — press once on, press again off. The classic light-switch logic: every press flips the output (ON→OFF, OFF→ON) and the state is retained after release. Like the wall switch at home. Best for lamps, socket switches, roller shutter stop/start — nearly any appliance that must hold its state. The most popular mode.

③ Interlock — one key ON, one key OFF. Requires learning two keys, an ON key and an OFF key. The ON key closes and holds, the OFF key opens; the two are mutually exclusive, so "both on" can never happen. Like an old-style two-button control. Best for motor forward/reverse, electric curtains and sliding gates — anywhere a single state must be guaranteed to prevent short circuits.

④ EV1527 batch — one remote, four timed functions. For EV1527 rolling-code remotes only. Learn with a single key press — the chip picks up all four buttons and binds them to different timers: A (code 0x08) → 30 s, B (0x04) → 60 s, C (0x02) → 180 s, D (0x01) → 600 s. Binding follows the learning order, not the letters printed on the remote. Best for garden lights, exhaust fans and greenhouse ventilation with several timer levels on one remote.

⑤–⑨ Timer — trigger, count down, switch off. One RF trigger closes the output, which then opens automatically after the selected time (10 / 30 / 60 / 180 / 600 s); no second press is needed. Like a corridor sound-activated light that goes dark by itself. Best for stairwell and garage lighting, bathroom extractor fans and hallway lamps — energy saving with five durations.

Frequency and receiver module

The chip decodes digital signals only — the RF frequency is set by the external receiver module. The same firmware works with any frequency; just swap the module.

  • 315 MHz — an earlier ISM band with good diffraction through walls; suited to short-range indoor use and legacy remote systems.
  • 433.92 MHz (recommended) — worldwide license-free ISM band; mature, low-cost modules with little interference, used by most 1527/2262 remotes.
  • Other bands — 868 MHz / 915 MHz also supported, simply fit a matching receiver module; no chip changes required.

Receiver and antenna tips: use a superheterodyne module such as SYN480R, RXB14 or AX5326 for production (better sensitivity and noise immunity); super-regenerative modules suit low-cost, short-range designs. Connect module DO to pin 7 (RF) and share the 2.5–5.5 V supply. A quarter-wave whip antenna (≈ 17 cm at 433 MHz, 23 cm at 315 MHz), kept clear of metal, typically gives 20–80 m open-field range.

Advantage over common alternatives

Most decoding solutions on the market are single-channel learning ICs or custom MCU firmware. ZWD832 is a finished, pre-programmed chip.

ComparisonCommon market solutionZWD832
ChannelsMostly single; dual products share one settingTrue dual independent — each learns and configures separately
Key bindingOne remote controls one channel as a wholeBind individual remote buttons (A/B/C/D → different functions)
ProtocolFixed to either 2262 or 1527EV1527 + PT2262 auto-detect, no switching
Output modesUsually momentary / toggle onlyMomentary, toggle, interlock, 5 timers, batch — 9 total
Timer optionsNone or one fixed duration5 selectable (10 / 30 / 60 / 180 / 600 s)
MemoryTypically 1–15 codes30-remote shared pool
Ease of useRequires encoding / programmingPre-programmed plug & play, learn by button
Supply rangeOften 5 V onlyWide 2.5–5.5 V — Li-ion, dry cell or 5 V rail
FrequencyFixedDecoupled from frequency — 315 / 433 / 868 MHz by module

In short: ZWD832 = dual independent channels + button-level binding + dual protocol + 9 modes + 5 timers + 30-code memory + plug & play. One IC replaces "two single-channel decoders plus a pile of logic" — ideal for dual-channel switches, motor reversing and multi-level timers.

Reference application circuit

A complete typical circuit: RF receiver interface, two transistor-driven relay channels, status LED, setting keys and power decoupling. Values are indicative — adapt them to your design.

ZWD832 reference application circuit schematic

Bill of materials

Ref.PartValue / model
U1Decoder ICZWD832, SOP-8
M1RF receiver433 MHz superheterodyne (SYN480R / RXB14)
Q1 / Q2NPN transistorS8050, β ≥ 150
J1 / J2Relay5 V, coil ≥ 100 Ω, SPDT
D2 / D3Flyback diode1N4148 across relay coil
D1Status LEDRed or green, with 3 kΩ resistor
S1 / S2Tactile switchSW-PB, SET1 / SET2, press to GND
R1Resistor3 kΩ — LED current limit
R2 / R4Resistor3 kΩ — Q1 / Q2 base resistor
R3 / R5Resistor10 kΩ — transistor base pull-down
C1Capacitor104 (100 nF) supply decoupling
ANTAntennaλ/4 whip ≈ 17 cm at 433 MHz

Layout essentials: place a 100 nF ceramic capacitor close to VCC/GND. Always fit a flyback diode (1N4148 / 1N4007) across each relay coil, cathode toward VCC. Route the receiver DO straight to pin 7 (RF) and keep the antenna away from metal and large copper pours.

Typical applications

  • Dual lighting control — one channel drives the main lamp, the other a secondary or ambient light; a single four-button remote controls both, with toggle and timer options.
  • Motor forward / reverse — two outputs drive an H-bridge for DC motor reversing, one channel per direction; interlock mode guarantees safety. Ideal for curtain motors, window openers and access gates.
  • Smart door access — one channel releases an electric strike in momentary mode, the other drives a doorbell or status indicator; suited to community gates, office locks and parcel lockers.
  • Wireless sockets — two outlets controlled independently, each learning its own remote; timer mode enables scheduled shutdown.
  • Garage shutter gate — one channel drives the motor open, the other closed; interlock mode prevents both at once. Suitable for garage doors, lifting platforms and electric gates.
  • Custom OEM designs — pre-programmed firmware and flexible modes shorten development time for any two-channel RF switching product.

SOP-8 package dimensions

ZWD832 SOP-8 package outline drawing

ParameterMin (mm)Typ (mm)Max (mm)
PackageSOP-8, 8 leads——
Body width (A)4.805.005.20
Body length (D)5.806.006.20
Lead pitch (e)1.27 BSC——
Lead width (b)0.310.400.51
Lead length (L)0.400.601.27
Overall width (E)5.806.006.20
Overall length (HE)8.6510.0010.35

BSC = Basic Spacing between Centers. Specifications are subject to change without notice.

Back to catalog