HMI-to-MCU Modbus RTU Control Kit for Machine Builders
Control integration where an industrial HMI panel acts as Modbus master and an embedded controller replaces discrete PLC logic over RS-485. Includes register map design, RTU slave firmware and wiring reference.
Request a quote for this model: info@zowinda.com
Technical specifications
| HMI software | Kinco HMIStudio |
|---|---|
| Physical layer | RS-485, 2-wire |
| Serial framing | 9600, 8N1, RTU |
| Slave address | 1 |
| Register model | 0x / 1x / 3x / 4x |
| Reference machine | Labeling machine control |
Protocols & interfaces
Overview
For compact machines, a full PLC can be unnecessary. In this architecture the HMI panel is the Modbus master and a low-cost MCU is the RTU slave. The panel renders the operator interface and polls registers; the MCU handles I/O, timing and interlocks.
Register model
| Prefix | Access | Typical content |
|---|---|---|
| 0x | Read / write | Coils — outputs and command bits |
| 1x | Read only | Discrete inputs — sensors and limit switches |
| 3x | Read only | Input registers — measured values, status words |
| 4x | Read / write | Holding registers — setpoints, timers, mode selection |
Wiring reference
On the HMI DB9 connector, pin 9 is TX+/A and pin 8 is TX-/B; connect ground as well. Default framing is RTU at 9600 baud, 8N1, slave address 1. Terminate the bus at both ends and keep the cable away from motor wiring.
| Item | Value |
|---|---|
| HMI A / TX+ | DB9 pin 9 |
| HMI B / TX- | DB9 pin 8 |
| Ground | Common ground required |
Deliverables
- C firmware for the MCU slave, with Chinese inline comments for manual review
- HMIStudio project setup steps, copied into the machine builder's own project
- Register map table agreed before firmware work starts
- Bench test procedure covering timeout, bus loss and output safe state
Documentation status
Register addresses and safe-state behaviour are machine-specific. Confirm the final map before release; never reuse a register map from another machine without review.